Fire Rated Steel Doors | Internal & External Fire Doorsets

Fire rating is an especially important part of steel door construction and certification for both internal and external doorsets. They should be engineered to protect people, property and be critical evacuation routes – all while delivering security, durability and long-term performance.

Configurations should also be independently tested in accordance with relevant UK standards and European test methods (BS EN) appropriate to their intended application.

What is EXAP for fire rated steel doors?

An EXAP (Extended Field of Application) report uses a recognised methodology within BS EN fire resistance standards to apply the tested performance of a fire rated steel doorset to versions that weren’t physically tested – such as different sizes, glazing, hardware and configurations.

This means that instead of testing every possible variation of a steel door with all the different components, EXAP uses validated fire-test data that predicts how similar designs will perform against fire – provided they meet certain strict criteria.

In the UK, EXAP typically follows the BS EN 15269 which sets out the EXAP rules for fire resisting and smoke control doorsets for doors, shutters and windows.

Following various safety improvements after the Grenfell fire, UK fire safety compliance has become more rigorous and evidence driven. Extending test results are only permitted through Direct Application (DIAP) or EXAP. BS 476 fire resistance references are also due to be removed from Approved Document B in England on 2 September 2029, making BS EN test evidence – and EXAPs based on it – increasingly important.

Additionally all performance must be classified under BS EN 13501-2 and verified by appropriate bodies so efficiency is increased and delays reduced. Without EXAP, every variation in hardware size or configurations would have to require separate fire testing.

EXAP reports have become a cornerstone of safety for modern fire rated steel doorsets, enabling tested performance to be applied across a wide range of projects and configurations without compromising safety or compliance.

Internal fire rated steel doors

Internal fire rated steel doors should ideally be positioned on all identified escape routes and corridors; in plant rooms and over service risers, around protected stair cores and in compartment walls between circulation spaces and higher-risk areas.

Also internal fire rated steel doors should provide between 30 and 120 minutes fire protection by being independently tested to BS EN 1634-1:2014+A1:2018.

Double fire rated internal steel doorset

External fire rated doors and UKCA/CE marking

External facing fire rated steel doors will have at least one side facing outside conditions and should be located on all protected and recognised escape routes, as access doors into stair cores or lobbies, in external plant rooms and substation doors and acting as perimeter doors when both security and fire resistance are important factors.

Importantly, external fire rated doors should be accredited to BS EN 14351-1:2006+A2:2016 and EN 16034:2014 and tested in accordance with BS EN 1634-1:2014+A1:2018. External doorsets placed on the market in Great Britain should also carry CE or UKCA (UK Conformity Assessed) marking to show that they conform with their declared performance under the applicable construction products standards. Sales in Northern Ireland require CE marking, or CE marking together with UKNI marking where a UK approved body has carried out the conformity assessment.

Commercial fire doors for non-domestic buildings

All doors located in commercial or non-domestic buildings including industrial, healthcare, leisure, hospitality, education, retail and public sector environments have to meet some typical requirements:

These include:

  • Maintain safe evacuation conditions for occupants, visitors and emergency services

  • Protect stair cores and vertical evacuation routes

  • Support compartmentation between floors and recognised escape routes

Additionally, good fire rated steel doors are particularly suitable in areas where there is high footfall or frequent use; when carts, trolleys or other equipment regularly impact doors and where long-life service and overall durability are key considerations.

Residential steel fire doors

Fire rated doors in residential settings are commonly required to support separation between higher-risk areas and designated escape routes. These can include:

  • Integral or attached garage doors into dwellings

  • Flat and apartment entrance doors opening onto a communal corridor, lobby or stairwell

  • Doors onto protected stairways in loft conversions and houses with three or more storeys – rooms opening onto the stairway (other than bathrooms and cloakrooms)

  • Mixed-use properties where a commercial unit adjoins residential accommodation

  • Boiler rooms or plant rooms

  • Bin stores and other service areas

Many homes use timber internal fire doors but steel residential fire rated doors are an even better solution when it comes to increased durability, security or specific performance criteria.

Steel vs timber fire doors: which is right for you?

When it comes to comparing steel or non-steel fire rated doors, there are a number of factors to consider. Non-steel (typically including timber) fire rated doors will:

  • Be commonly specified in the UK as FD30 or FD60 (tested to BS 476-22), or as E30/EI30 and E60/EI60 under BS EN 13501-2, providing 30 to 60 minutes fire resistance

  • Be well suited to commonly low-risk domestic interiors and lighter-duty settings

  • Be possibly more susceptible to impact, moisture and warping over time, especially if they are in high-traffic or humid environments

Steel rated fire doors will:

  • Routinely achieve longer periods of fire resistance, up to E120 or EI120 (2 hours), depending on the tested configurations

  • Provide higher structural integrity – meaning they are less likely to deform under heat or heavy use

  • Combine fire performance with security and thermal upgrades within in a single doorset

  • Be ideal for industrial, commercial of other high-risk areas where damage, downtime and premature replacement are costly

A note on fire ratings: Under BS EN 13501-2, “E” denotes integrity only – the door’s ability to prevent flames and hot gases passing through. “EI” adds insulation, which limits the temperature rise on the unexposed face of the door (classified as EI1 or EI2). FD ratings, such as FD30 and FD60, are the traditional UK classification from BS 476-22 testing, with an “S” suffix (e.g. FD30S) indicating smoke control.

For business owners or specifiers comparing their options, the decisions can come down to:

  • What is the building use, occupancy and risk-level? How many people would need to be taken into consideration and what is the complexity of evacuation routes?

  • What is the required fire rating?

  • What durability and impact resistance is required? Especially in plant rooms, service corridors and external doors. (Steel doors will outlast timber alternatives when properly maintained)

  • What is the whole life cost of the doorset?

 

FAQs

What is a fire rated door?

The official definition of a fire rated door is a doorset that has been tested as a complete assembly (or EXAP) to resist fire for a defined period – typically 30, 60 or 120 minutes. It’s designed to contain fire and / or smoke within a compartment, protecting escape routes and giving occupants sufficient time to evacuate

What do E30, E60s and EI30 fire door ratings mean?

The number in each rating is the minimum time in minutes the doorset has resisted fire in testing – so all three relate to 30 minutes. The letters tell you how it was tested and what it protects against:

  • E30 – a European classification under BS EN 13501-2, based on testing to BS EN 1634-1. “E” stands for integrity only: the door stops flames and hot gases passing through for 30 minutes, but it does not limit heat transfer to the other side.

  • E60S – the traditional UK rating from BS 476-22 testing. “E60s” means 60 minutes’ fire resistance, and the “S” means the door also restricts the passage of smoke, usually through smoke seals. Smoke control under the European system is shown by an additional “Sa” (cold smoke) suffix, e.g. E60sa or an “S200” (elevated temperature) suffix e.g. E60s200.

  • EI30 – integrity plus insulation (“I”) for 30 minutes. As well as containing flames and gases, the door limits the temperature rise on the side away from the fire, classified as EI1 or EI2. This is important where people or combustible materials may be close to the door.

For buyers, the key is to match the rating to what the building’s Fire Strategy Report or specification requires – a door with integrity only is not a like-for-like substitute where insulation is specified. If you are unsure, ask the manufacturer for the test evidence or a classification report covering the exact doorset configuration.

 

What evidence should I ask a fire door manufacturer for?

A fire rating is only as reliable as the evidence behind it. Before specifying or buying fire rated doorsets, ask the manufacturer for:

  • Fire test reports – showing the doorset was tested to BS EN 1634-1 by an accredited laboratory, and which configurations were tested

  • EXAP report – where the door differs from the tested specimen (for example in size, glazing or hardware), an Extended Field of Application report prepared to BS EN 15269 by an approved body, confirming the variation is covered

  • Classification report – confirming the rating achieved under BS EN 13501-2, such as E60 / E120.

  • Declaration of Performance and CE or UKCA marking – for external doorsets covered by BS EN 14351-1 and EN 16034

  • Installation and maintenance instructions – including approved frames, fixings, seals and ironmongery, as the rating depends on the doorset being installed and maintained as tested

Check that the evidence covers the exact doorset being supplied – its size, leaf configuration, glazing and hardware – and that it is current. Your fire engineer, building control body or fire risk assessor can help confirm the evidence meets the project’s Fire Strategy Report.

To request the fire test, EXAP or classification evidence for a Metador fire rated steel doorset, contact our team with your project details and we’ll share the documentation that covers your specification.

Can fire rated doors also provide thermal performance?

Yes – under certain configurations, thermal performance values can be achieved that may support compliance with Building Regulations Part L, subject to building design and door specifications

What’s the difference between a fire rated door and a fire exit door?

Fire exit doors are focused on allowing people to escape safely and quickly, typically using panic hardware which may or may not have a fire rating. A fire rated door is designed to resist fire for a specified period of time.

In many buildings, both will be required often in different locations while in some cases a door can be both a fire exit and fire rated provided that it has been tested and specified correctly.

A stairwell door, for example, could be an FD30S fire door that is also on the escape route. In that case both sets of rules apply. In this scenario any exit hardware would need to have been fire tested with the fire door when one door needs to meet both requirements.

Can fire rated steel doors have glass vision panels?

Yes – provided the glazing system has been tested as part of the fire rated doorset. The glass, beads, glazing seals, fixings, door leaf and frame must form a complete tested assembly, and ordinary toughened or laminated glass is not automatically fire rated. Key points to consider:

  • E vs EI glazing – integrity-only (E) fire glass, such as wired or some laminated types, stops flames and smoke but not radiant heat. Insulating (EI) fire glass, typically with intumescent interlayers, turns opaque in a fire to block heat as well, and is generally needed for larger panels, longer fire ratings or wherever the specification calls for insulation. The glazing should always match the rating of the doorset.

  • Tested panel sizes and positions – the size, shape and position of a vision panel must fall within the configurations covered by the manufacturer’s fire test or EXAP report. Panels should never be cut or enlarged on site; non-standard layouts should be manufactured and certified to that specific design.

Manufacturers like Metador can build bespoke fire rated doorsets with vision panels to precise specifications, sizes and finishes.

Do I legally need fire rated doors in a building?

There is no single UK law that says every building must have fire doors. Whether they are legally required depends on the building, the work being carried out and where the door is located. In England, two main legal regimes apply:

  • Building Regulations (Part B) – new buildings, extensions, changes of use and other building work must meet Part B (fire safety) of the Building Regulations 2010. Approved Document B sets out where fire-resisting doors are needed, such as protected stairways, escape routes, compartment walls and doors between a house and an integral garage.

  • Regulatory Reform (Fire Safety) Order 2005 – applies to buildings in use, including virtually all non-domestic premises and the common parts of blocks of flats in England and Wales. The responsible person (usually the employer, owner or person in control of the premises) must protect escape routes – in practice, providing fire doors wherever the fire risk assessment identifies them – and keep them maintained in efficient working order and good repair.

Building regulations and fire safety law are set separately in England, Wales, Scotland and Northern Ireland, so the detailed requirements differ depending on where the building is located. Scotland and Northern Ireland have their own building standards and fire safety legislation, and Wales has its own Building Regulations guidance.

In non-domestic buildings, stair cores, corridors, plant rooms and other high-risk areas will almost always require appropriately fire rated doors. A fire risk assessor, fire engineer or building control body can confirm the exact requirements for your building, as set out in its Fire Strategy Report.