Fire rating is an especially important part of steel door construction and certification for both internal and external doorsets. They should be engineered to protect people, property and be critical evacuation routes – all while delivering security, durability and long-term performance. Configurations should also be independently tested in accordance with relevant UK standards and European test methods (BS EN) appropriate to their intended application. What is EXAP for fire rated steel doors?An EXAP (Extended Field of Application) report uses a recognised methodology within BS EN fire resistance standards to apply the tested performance of a fire rated steel doorset to versions that weren’t physically tested – such as different sizes, glazing, hardware and configurations. This means that instead of testing every possible variation of a steel door with all the different components, EXAP uses validated fire-test data that predicts how similar designs will perform against fire – provided they meet certain strict criteria. In the UK, EXAP typically follows the BS EN 15269 which sets out the EXAP rules for fire resisting and smoke control doorsets for doors, shutters and windows. Following various safety improvements after the Grenfell fire, UK fire safety compliance has become more rigorous and evidence driven. Extending test results are only permitted through Direct Application (DIAP) or EXAP. BS 476 fire resistance references are also due to be removed from Approved Document B in England on 2 September 2029, making BS EN test evidence – and EXAPs based on it – increasingly important. Additionally all performance must be classified under BS EN 13501-2 and verified by appropriate bodies so efficiency is increased and delays reduced. Without EXAP, every variation in hardware size or configurations would have to require separate fire testing. EXAP reports have become a cornerstone of safety for modern fire rated steel doorsets, enabling tested performance to be applied across a wide range of projects and configurations without compromising safety or compliance. Internal fire rated steel doorsInternal fire rated steel doors should ideally be positioned on all identified escape routes and corridors; in plant rooms and over service risers, around protected stair cores and in compartment walls between circulation spaces and higher-risk areas. Also internal fire rated steel doors should provide between 30 and 120 minutes fire protection by being independently tested to BS EN 1634-1:2014+A1:2018.
External fire rated doors and UKCA/CE markingExternal facing fire rated steel doors will have at least one side facing outside conditions and should be located on all protected and recognised escape routes, as access doors into stair cores or lobbies, in external plant rooms and substation doors and acting as perimeter doors when both security and fire resistance are important factors. Importantly, external fire rated doors should be accredited to BS EN 14351-1:2006+A2:2016 and EN 16034:2014 and tested in accordance with BS EN 1634-1:2014+A1:2018. External doorsets placed on the market in Great Britain should also carry CE or UKCA (UK Conformity Assessed) marking to show that they conform with their declared performance under the applicable construction products standards. Sales in Northern Ireland require CE marking, or CE marking together with UKNI marking where a UK approved body has carried out the conformity assessment. Commercial fire doors for non-domestic buildingsAll doors located in commercial or non-domestic buildings including industrial, healthcare, leisure, hospitality, education, retail and public sector environments have to meet some typical requirements: These include:
Additionally, good fire rated steel doors are particularly suitable in areas where there is high footfall or frequent use; when carts, trolleys or other equipment regularly impact doors and where long-life service and overall durability are key considerations. Residential steel fire doorsFire rated doors in residential settings are commonly required to support separation between higher-risk areas and designated escape routes. These can include:
Many homes use timber internal fire doors but steel residential fire rated doors are an even better solution when it comes to increased durability, security or specific performance criteria. Steel vs timber fire doors: which is right for you?When it comes to comparing steel or non-steel fire rated doors, there are a number of factors to consider. Non-steel (typically including timber) fire rated doors will:
Steel rated fire doors will:
A note on fire ratings: Under BS EN 13501-2, “E” denotes integrity only – the door’s ability to prevent flames and hot gases passing through. “EI” adds insulation, which limits the temperature rise on the unexposed face of the door (classified as EI1 or EI2). FD ratings, such as FD30 and FD60, are the traditional UK classification from BS 476-22 testing, with an “S” suffix (e.g. FD30S) indicating smoke control. For business owners or specifiers comparing their options, the decisions can come down to:
FAQsWhat is a fire rated door?The official definition of a fire rated door is a doorset that has been tested as a complete assembly (or EXAP) to resist fire for a defined period – typically 30, 60 or 120 minutes. It’s designed to contain fire and / or smoke within a compartment, protecting escape routes and giving occupants sufficient time to evacuate What do E30, E60s and EI30 fire door ratings mean?The number in each rating is the minimum time in minutes the doorset has resisted fire in testing – so all three relate to 30 minutes. The letters tell you how it was tested and what it protects against:
For buyers, the key is to match the rating to what the building’s Fire Strategy Report or specification requires – a door with integrity only is not a like-for-like substitute where insulation is specified. If you are unsure, ask the manufacturer for the test evidence or a classification report covering the exact doorset configuration.
What evidence should I ask a fire door manufacturer for?A fire rating is only as reliable as the evidence behind it. Before specifying or buying fire rated doorsets, ask the manufacturer for:
Check that the evidence covers the exact doorset being supplied – its size, leaf configuration, glazing and hardware – and that it is current. Your fire engineer, building control body or fire risk assessor can help confirm the evidence meets the project’s Fire Strategy Report. To request the fire test, EXAP or classification evidence for a Metador fire rated steel doorset, contact our team with your project details and we’ll share the documentation that covers your specification. Can fire rated doors also provide thermal performance?Yes – under certain configurations, thermal performance values can be achieved that may support compliance with Building Regulations Part L, subject to building design and door specifications What’s the difference between a fire rated door and a fire exit door?Fire exit doors are focused on allowing people to escape safely and quickly, typically using panic hardware which may or may not have a fire rating. A fire rated door is designed to resist fire for a specified period of time. In many buildings, both will be required often in different locations while in some cases a door can be both a fire exit and fire rated provided that it has been tested and specified correctly. A stairwell door, for example, could be an FD30S fire door that is also on the escape route. In that case both sets of rules apply. In this scenario any exit hardware would need to have been fire tested with the fire door when one door needs to meet both requirements. Can fire rated steel doors have glass vision panels?Yes – provided the glazing system has been tested as part of the fire rated doorset. The glass, beads, glazing seals, fixings, door leaf and frame must form a complete tested assembly, and ordinary toughened or laminated glass is not automatically fire rated. Key points to consider:
Manufacturers like Metador can build bespoke fire rated doorsets with vision panels to precise specifications, sizes and finishes. Do I legally need fire rated doors in a building?There is no single UK law that says every building must have fire doors. Whether they are legally required depends on the building, the work being carried out and where the door is located. In England, two main legal regimes apply:
Building regulations and fire safety law are set separately in England, Wales, Scotland and Northern Ireland, so the detailed requirements differ depending on where the building is located. Scotland and Northern Ireland have their own building standards and fire safety legislation, and Wales has its own Building Regulations guidance. In non-domestic buildings, stair cores, corridors, plant rooms and other high-risk areas will almost always require appropriately fire rated doors. A fire risk assessor, fire engineer or building control body can confirm the exact requirements for your building, as set out in its Fire Strategy Report.
|